中文版 | English
Current Position:Home > Products > Filter > Hydac Filter >
Hydac Filter
RFLD Double Line filter
Date:2013-01-14 14:38
RFLD Double Line filter




1.MODEL COLD
RFLD  BN/HC  1300   C     A    K   10     D    1      X   
 (1)           (2)        (3)    (4)  (5)  (6)  (7)   (8)  (9)   (10)
Detailed Explanation :
 (1)RFLD: The form of filter
(2)BN/HC : Material of filter element    
 BN/HC ,W/HC
(3)1300: Specification
  1300/1320/2500/2520/4000/4020/5200/5220/6500/6520/7800/7820/5000/5020
(4)C:Working pressure       C=16bar
(5)A : Switching valve forms     
(6)K : Connection Type / Specifications
(7)10:Filtration precision (μm)    
  BN/HC ,BH/HC : 3,5,10,20
  P/HC : 10,20
  W/HC : 25,50,100,200
(8)D :Form of pollution sender device 
A : Mounting holes closed indented bolts
B: With visual pollution sender
C: With electrical pollution sender
D: Visual / electrical pollution sender
(9)1: standard connector
  (10)X : Latest version
2.Parameter
   Flow : 15000L/min
Material : Welded carbon steel / stainless steel
Pressure : 16bar

3.Matching the filter description

Specification : 0950/1300/1700/2600
Form :  R  
   Filtration precision (μm) :   
      BN/HC : 3,5,10,20
      W/HC: 25,50,100,200
Filter material : BN/HC ,P/HC,W/HC